Strong Heating Split Air Conditioner 18,000BTU

Split Wall Type Air conditioner 

Wall mounted air conditioner 



Tropical Heating Air Conditioner

With ambient temperature -20 °C , internal air outlet temperature can be up to 50 °C, it is truly a good product that can meet the heating needs of ultra cold areas.

 

 

The lower the ambient temperature, the stronger the heating

With ambient temperature -20 °C,heating capacity is 110% of the Rated Heat capacity.


,
Model DRK-40GW/LFG052aBpA1 DRK-60(100)GW/08aBpA1 DRKC-40/52/30GW/LFG056aBpA1 CLR-30L/35/45GW/06fBpC1++
DRK-40GW/LFG056aBpA1
Rated Dehumidity  L/D (30°C/80%RH) - - 30 30
Norminal Dehumidity Kg/H (27°C/60%RH) - - 0.8 0.8
Nominal Dehumidity Input Power W - - 380 285
Dehumidity Per H.KW Kg/H.K w - - 2.1 2.8
Dehumidity Opearting Noise Level dB(A) - - 28/32 28/32
Dehumdity Ambient Working Temperature °C - - 5~40 5~40
Dehumidity Working Area - - 40~120 40~120
Power Supply V/PH/Hz 220/1/50 220/1/50 220/1/50 220/1/50
Rated Cooling Capacity W 600-5300 800-7600 600-5300 600-4200
Rated Cooling Input Power W 200-2000 250-3500 200-2000 200-1350
Rated Heating Capacity W - - - 500-5200
Rated Heating Input Power W - - - 200-1460
Nornimial heating Capacity(-12°C) W 4000 6000 4000 -
Low Temperature Heating Input Power(-12°C) W 1550 2330 1550 -
Nornimial heating Capacity(-20°C) W 4400 6600 4400 -
Low Temperature Heating Input Power(-20°C) W 2230 3150 2230 -
Noise Level Indoor Unit dB(A) 30-42-45 38-44-46 30-42-45 24-37-41
Outdoor Unit dB(A) 54 57 54 52
Refrigerant Type - R32 R32 R32 R32
Unit Weight Indoor unit Kg 10 16 10 11
Outdoor unit Kg 31 48 31 31
Indoor Unit Dimension L*W*H mm 890*322*215 890*322*215 890*322*215 890*322*215
Outdoor Unit Dimension L*W*H mm 874*559*368 874*559*368 874*559*368 874*559*368
Max. Suction Pressure Mpa 2.5
Max. Exhaust Pressure Mpa 4.3
Max. Operating Pressure Mpa 4.3
AC Ambient Working Temperature °C -35~60 -35~60 -35~60 -12~60
AC Working Area 21~31 33~45 21~31 15~22
,